Search
- Sensor Helps Produce Flat Film
- (Controls)
- November 30, 2010, ... of clear, filled, voided, and pearlized films with a patented optical design, selection of discrete near-IR wavelengths, and sensor algorithms. Measurement capability reportedly helps produce flat film ...
- Using Electrostatic Voltmeters
- (Static Elimination)
- November 30, 2010, ... When using an electrostatic voltmeter to diagnose a static problem, or when selecting a voltmeter for a specific application, three performance measures are important: measurement range, spatial resolution, ...
- Static Beat: How To Use Electrostatic Fieldmeters
- (Static Elimination)
- October 31, 2010, ... 1 shows three measurement locations: EMIDDLE, taken midway between rollers; ENEAR, taken near a roller; and EROLLER, taken directly over a roller. The electric fieldmeter reading EMIDDLE is the most ...
- Measure Multiple Components
- (Controls)
- October 31, 2010, The InfraSpec VFA-IR spectrometer is well suited for handling multiple flexible film measurements with one instrument. This spectral range analyzer utilizes The InfraSpec VFA-IR spectrometer is well suited ...
- Process Troubleshooting
- (Coating/Laminating)
- October 31, 2010, ... and is defined as defect levels below 3.4 defects per million opportunities. It is important that the defect and the opportunity are correctly defined or the measurement is useless. Six Sigma doctrine ...
- Flexographic Printing: Super Setup
- (Inspection/Defect Detection)
- September 30, 2010, ... with our X-Rite [color measurement] unit. It is a very reliable system for color management and has helped us a lot,” Abascal says. He also has seen improvement in other areas. “We are producing more ...
- ICE USA Stirs Up More Activity
- (Yo's Yarns)
- September 20, 2010, ... be given between 10–12 P.M. each day, running on four different tracks: Measurement/Quality; Package Printing/Converting; Process; and Web Handling. Pricing for the conference sessions will be $79 for ...
- Static Beat: Monitor Process with a Control Chart
- (Static Elimination)
- August 31, 2010, ... the minimum and maximum average measurements that are expected from a process that is running normally. The Xbar control chart shows that high electric fields measured on rolls 6, 7, and 8 exceed the UCL, ...
- Measure Length Precisely
- (Controls)
- August 31, 2010, ... back to the LaserSpeed unit. Data is translated into product speed, and pulses are produced to determine product length. Company says length and speed measurements are captured with better than +0.05% ...
- Converter Industry Events
- (News Clips Archive)
- August 31, 2010, ... 7-8 | Winding: Machines, Mechanics & Measurements, AIMCAL Converting School, Crowne Plaza Downtown, Philadelphia, PA; www.convertingschool.com 17-20 | AIMCAL Fall Technical Conference, Assn. of Industrial ...
- Device Helps Deliver Precise Rollers
- (Web Handling)
- July 31, 2010, Company uses the TruShape2 measuring device to provide in-process measurement capabilities said to help deliver rollers with superior precision. This Company uses the TruShape2 measuring device to provide ...
- Measure Temps Without Contact
- (Controls)
- July 31, 2010, MI3 IR noncontact temperature measurement sensors are said to deliver high performance and flexibility. Features include a broad choice of sensing head MI3 IR noncontact temperature measurement sensors ...
- Static Beat: How To Take a Static Survey
- (Static Elimination)
- July 31, 2010, ... used two different strategies for taking static measurements for process verification and to help diagnose problems: Static Surveys and Control Charts. Both methods establish baseline measurements for ...
- Show Preview: Heroes Welcome-Labelexpo Americas 2010
- (Label/Tape)
- July 31, 2010, ... range of LaserSpeed noncontact encoders in Booth 3743. The company says length and speed measurements are captured with better than +0.05% accuracy. Nilpeter will show five prsses in Booths 3105 and ...
- Laminating Corona Treating: Bond Boosting
- (Corona, Flame, Plasma)
- July 31, 2010, ... are used to do quick dyne level checks of the substrates before and after treatment. Dynes are a unit of measurement used to measure surface energy and generally provide a good indication of wettability ...
- Torbar Tubes Are Economical Flow Metering Solution
- (Controls)
- July 25, 2010, ... pressure and temperature compensation for mass flow measurement. Cost savings discussed include less wiring and piping, driving down installed costs by as much as 60%. This flowmeter also eliminates need ...
- MOCON Moves, Expands Lab
- (Controls)
- July 22, 2010, ... laboratory functions. The move was prompted by increased worldwide demand for the company’s test and measurement instrumentation as well as its laboratory testing capabilities. The new site totals 60,000 ...
- Static Beat: Choosing Passive or Active Ionizers
- (Static Elimination)
- June 30, 2010, ... use your electrostatic fieldmeter to take some measurements. I have used two different measurement strategies: make a control chart or complete a static survey. Both strategies are effective, so you can ...
- Special Report: Quality Protocols-Quality Assures Security
- (Label/Tape)
- June 30, 2010, ... a label house; we consider ourselves a manufacturer,” says Dobert. “We have a unique quality system because we deal with a lot of measurements. In the past ten years, we literally taught all of our personnel ...
- Measure Intensity & Dose
- (Coating/Laminating)
- June 30, 2010, The Accu-Cal 50-LED radiometer is said to offer accurate intensity and dosage measurements for LED curing equipment. Photo-sensor assembly provides repeatable The Accu-Cal 50-LED radiometer is said to ...